Energy-Dispersive X-ray Sulfur-in-Oil Analyzer ECROS-7700
16 028 $ add to cart
The price is valid for non-residents of the Russian Federation
The ECROS-7700 energy dispersion sulfur analyzer (3ppm) is designed to determine the mass fraction of sulfur from 2 mg/kg to 100,000 mg/kg in crude oil, gasoline (unleaded), diesel fuel, kerosene, oil residues, lubricating oil bases, hydraulic oils, jet fuel and other distillate petroleum products in accordance with GOST R 51947-2002, GOST 32139-2013, GOST ISO 8754-2013, ASTM D 4294-16, ISO 8754-2003.
The analyzer can be used in laboratories of the oil production and refining industry, laboratories of oil pipelines and petroleum product pipelines, laboratories of research and educational institutions, as well as for research in the field of ecology and environmental protection.
Features:
- Quick analysis without sample preparation;
- Full compliance with the hardware, methodological and metrological requirements of all listed regulatory documents, including:
1. calibration according to standard samples of petroleum products;
2. automatic compensation of the influence of the hydrocarbon matrix (C/H ratio) on the measurement results of any types of petroleum products, implemented using the calculation of the radiation intensity from the measured samples in two energy zones:
sulfur radiation K-L =2.3 keV;
2.3 scattered radiation from the hydrocarbon base of the Bs matrix in any region of the energy range of dispersion.
- Correction of the calibration hardware drift according to the Installation Samples (Set-Up Standards);
- The possibility of correcting the hardware drift using the zero sample compensation method;
- The possibility of extending the range of determination of the mass fraction of sulfur to 10.0 %;
- Convenient disposable measuring cuvettes;
- Color touch screen display;
- Simple user interface;
- Data output to the display, built-in printer and serial port;
- Ethernet interface for LAN and LIMS systems and USB ports for connecting peripheral devices for digital sample identification (barcodes, RFID);
- Blocking the activation of the X-ray source with a mechanical switch lock;
- Durable metal housing guarantees reliable protection against X-rays and industrial external electromagnetic radiation;
- Compact and light weight;
- Availability of all consumables (cuvettes, film, CO, GSO) of own production.
Technical specifications:
- The range of determination of the mass fraction is from 5 mg/kg to 50,000 mg/kg;
- The range of indications for determining the mass fraction is from 2 mg/ kg to 100,000 mg/kg;
- The limit of the permissible absolute error in measuring the mass fraction of sulfur, mg /kg:
- in the range from 3 mg/kg to 16 mg/kg ± 1.3041 C0,6446;
- in the range above 16 mg/kg to 46,000 mg/kg ± 0.8694 C0,6446;
- in the range above 46,000 mg/kg to 50,000 mg/kg ± 1,7388 C0,6446;
where C is the measured value of the mass fraction of sulfur, mg/kg/;
- The relative standard deviation of the COE of the random component of the error when measuring the mass fraction of sulfur 500 mg / kg - no more than 0.5%;
- The repeatability limit of the results of single measurements of the mass fraction of sulfur r (P = 0.95), mg /kg:
-in the range from 3 mg/kg to 16 mg/kg r=0.8694 C0,6446;
-in the range of sv. 16 mg/kg to 46,000 mg/kg r=0.4347 C0,6446;
-in the range of sv. 46,000 mg/kg to 50,000 mg/kg r=1.3041 C0,6446;
where C is the measured value of the mass fraction of sulfur, mg/kg.
- The theoretical limit of detection in 600 seconds is less than 4.0 mg/kg;
- The counting rate on the molybdenum (SU-Mo) installation sample is at least 10000 pulses/s;
The limit of the relative error of the analyzer when measuring the counting rate at SU-Mo is no more than 0.5%
if the following conditions are met:
-ambient temperature: +(20±5)° C;
-relative humidity: from 45% to 80 %;
-atmospheric pressure: from 84 kPa to 107 kPa;
-deviation of the mains supply voltage from the nominal value, not more than: ± 2 %;
-Network frequency: (50/60)±1 Hz;
-absence of mechanical influences and magnetic fields (except terrestrial);
- The analyzer's continuous operation time is at least 17 hours;
- Average time to failure - at least 15,000 hours;
- The specified time to failure is provided if the consumer complies with the operating conditions and takes measures providing for technical and repair maintenance of the analyzer;
- The analyzer is powered by an AC power supply with a frequency of (50/60)* 1 Hz and a voltage of (100-240) V ± 10 %;
- The power consumed by the analyzer is not more than 90 V *A;
- Overall dimensions of the analyzer - no more than 290x390x145 mm;
- Analyzer weight - no more than 8 kg;
- The analyzer has built-in software for data management and processing;
- The connections of the following communication interfaces are located on the back panel of the analyzer housing:
- Two USB connectors of type A – standard GOST R IEC 62680-4-2015, designed for connecting external media;
- Ethernet connector of the 100BaseTX protocol - IEEE Std 802.3ab-1999 standard, designed for interaction with the analyzer over a local network;
- RS232 connector – GOST 18145-81 standard, designed for connecting external devices.
Transport data/dimensions/weight:
1 box, 560 x 380 x 250 mm. Weight 11.5 kg
Basic equipment:
- Sulfur analyzer X-ray fluorescence energy dispersive EKROS–7700 - 1 pc.;
- Network cable - 1 pc.;
- Protective cuvette - 1 pc.;
- Set of installation samples - 1 set;
- Measuring cuvette KI-28 - 50 pcs.;
- Mylar film - 2 rolls;
- Thermal paper for the built-in printer 57mm x30m x 12mm - 6 rolls;
- Switch lock key - 2 pcs.;
- Backup USB flash drive - 1 pc.;
- Device for disassembling cuvettes KI-28 - 1 pc.;
- Device for disassembling protective cuvettes - 1 pc.;
- Stylus for touch screen - 1 pc.;
- Passport Operating manual BKRE.415312.003PS - 1 copy;
- Copy of the expert opinion on radiation safety - 1 copy.